Home   |   Company   |   Cooling Tower   |    Heat Exchanger   |    Air Dryer   |    Water Softner   |    Fiber Glass Tank   |    Enquiry   |    Contact

COMPRESSED AIR DRIERS DIVISION

Heat Less Compressed Air Driers   |   Refrigerated Air Driers   |   Spares  |    Services     
Compressed air driers are used to avoid the contamination problems in the compressed Air. The Air driers are two types. One is Heatless Compressed Air drier and another one is Refrigerated Air Drier.

HEAT LESS COMPRESSED AIR DRIERS


These types of Air Driers are designed to take advantage of the natural tendency of desiccants to establish equilibrium with their surroundings and to deliver dry and clean air used for pneumatic instrumentation or critical applications.

The drier consist of two towers with beds of activated alumina absorbent desiccants. The System completes with prefilter, oil filter, after filter and also with necessary valves, pipelines, fittings, timers and electrical items etc. When the wet air from the compressor enters in the bottom of alumina filled tower losses all its moisture contents and the dry air exists at the top of the tower. Due to absorption all the desiccants were saturated. Then an automatic timer diverts incoming air to another tower. When one tower is drying the air, the other tower regenerates the desiccants. This is a self contained Process, which uses a purge of already dried air to pass through the desiccant bed at lower pressure. This Purge air removes the absorbed moisture from the absorbent desiccant.

This process is automatically reversed from one tower to the other on a timed sequence basis [5 minutes drying and 5 minutes regenerating].

The drier is fixed on a base frame with all accessories and in a ready condition to operate. Mere bed bolt is enough to erect the driers. A rain, dust and moisture free room is preferable for erection. Adequate floor clearance and the surrounding temperature should be normal level around the drier is required. To get the best result the inlet air to be sufficiently cool [between 25 deg C to 40 deg C]. So an after cooler is necessary to get the above level. Optimum size of Tower is used to avoid excess usage of purge air pressure drop excess desiccant dust and obtain a better result of 40 deg C dew point. All types of spares are ready stock to avoid customer's break down problem. Capacities ranges from 5CFM to 5000CFM.



REFREGERATED AIR DRIERS

This type of air drier is compact in size and easy principle. Mere Condensation of moisture in air by cooling. The Specialty of this type drier is without purge air loss. Since this type of drier is based on refrigerant principle there will be no question of carry over of desiccant contamination . This should remove all unwanted moisture from compressed air. So we can safe guard all our instrumentation items from moisture and corrosion.
1.AFTER COOLERS:
Air and water Cooled Systems are used. Air-cooled after coolers are normally recommended for small capacities to reduce initial cost and get a better result where water-cooled after coolers are recommended for all capacities. With a shell & tube Heat Exchanger, the heated Air is condensate up to 75% level before dryer operation.
2.MOISTURE SEPERATOR:
It is used in the system to reduce the moisture contents and filter the air upto 10-micron rate without losing line pressure.
3.ELECTRONIC AUTOMATIC DRAIN VALVES:
This is to drain the condensate water from dryers, moisture separators etc. It eliminates manual operation.
4.OIL FILTER:
The oil particles in the system Air from the compressor head is completely removed by using activated carbon filter.
5.MINI AIR DRYER:
This is supplied for small capacities with all accessories Viz: Prefilter, alumina absorber and oil filter in a single connection system.
6.OTHER PRODUCTS RANGE:
Air Receiver Tanks, Dew point indicator, control panel Inter/After Coolers etc.






SPARES


Exhaust Valve
Main Flow Valve
Pilot Operated Valve
Needle Valve
Non-Return Valve
Solenoid Valve
Automatic Drain Valve









SERVICES

UNDERTAKE ALL REPAIR & SITE DESCALING:

Undertaking site servicing and repairing of Cooling Towers, Boilers, Heat Exchangers, Oil Coolers, Genset water lines and other cooling systems.









Home   |   Company   |   Cooling Tower   |    Heat Exchanger   |    Air Dryer   |    Water Softner   |    Fiber Glass Tank   |    Enquiry   |    Contact